Model | Nominal Voltage | Nominal Capacity | Stored Energy | Dimensions(mm) | Number of Module Methods | Case Weight Standard | Casing Material | IP Rating |
---|---|---|---|---|---|---|---|---|
B-LFP24-100MH | 25.6V | 100Ah | 2.56kWh | Support Customized | 1P*8S*1 | 42kg( 88.18lbs. ) | Steel | IP65 |
B-LFP24-135MH | 135Ah | 3.46kWh | 1P*8S*1 | 62kg( 136.69lbs. ) | ||||
B-LFP24-173MH | 173Ah | 4.43kWh | 1P*8S*1 | 62kg( 136.69lbs. ) | ||||
B-LFP24-205MH | 205Ah | 5.25kWh | 1P*4S*2 | 80kg( 176.37lbs. ) | ||||
B-LFP24-230MH | 230Ah | 5.89kWh | 1P*8S*1 | 85kg( 187.39lbs. ) | ||||
B-LFP24-280MH | 280Ah | 7.17kWh | 1P*8S*1 | 97kg( 213.85lbs. ) | ||||
B-LFP24-304MH | 304Ah | 7.78kWh | 1P*8S*1 | 102kg( 224.87lbs. ) | ||||
B-LFP24-346MH | 346Ah | 8.86kWh | 2P*4S*2 | 119kg( 262.35lbs. ) | ||||
B-LFP24-410MH | 410Ah | 10.50kWh | 2P*4S*2 | 142kg( 313.06lbs. ) | ||||
B-LFP24-460MH | 460Ah | 11.78kWh | 2P*4S*2 | 156kg( 343.92lbs. ) | ||||
B-LFP24-519MH | 519Ah | 13.29kWh | 3P*4S*2 | 171kg( 376.99lbs. ) | ||||
B-LFP24-560MH | 560Ah | 14.34kWh | 2P*4S*2 | 181kg( 399.04lbs. ) | ||||
B-LFP24-608MH | 608Ah | 15.56kWh | 2P*4S*2 | 190kg( 418.88lbs. ) | ||||
B-LFP24-615MH | 615Ah | 15.74kWh | 3P*4S*2 | 191kg( 421.08lbs. ) | ||||
B-LFP24-690MH | 690Ah | 17.66kWh | 3P*4S*2 | 210kg( 462.97lbs. ) | ||||
B-LFP24-840MH | 840Ah | 20.99kWh | 3P*2S*4 | 244kg( 537.93lbs. ) | ||||
B-LFP24-920MH | 920Ah | 23.55kWh | 4P*2S*4 | 270kg( 595.25lbs. ) | ||||
B-LFP24-1120MH | 1120Ah | 28.67kWh | 4P*2S*4 | 317kg( 698.87lbs. ) | ||||
Enviroment Temp. Range | Charge:-20℃~55℃(-4℉~131℉) | Discharge:-20℃~55℃(-4℉~131℉) | Storge:-20℃~55℃(-4℉~131℉) |
Verify battery capacity and charge/discharge performance to ensure stable output without overheating or early degradation.
Use temperature cycling and thermal shock tests to confirm reliable operation under extreme and changing climates.
Conduct vibration, drop, and crush tests to ensure the battery structure remains intact during transport and tough conditions.
Test under short circuit, overcharge, and over-discharge conditions to prevent fire, leakage, or explosion.
Confirm compliance with international standards such as UL2580, UL2271, UL583 Type EE, and UN38.3 for safe handling and transport.